Hostname: page-component-76fb5796d-9pm4c Total loading time: 0 Render date: 2024-04-29T12:18:54.999Z Has data issue: false hasContentIssue false

453 Rapid SARS-CoV-2 testing with duplexed recombinase polymerase amplification and a bacteriophage internal control

Published online by Cambridge University Press:  24 April 2023

Coleman Martin
Affiliation:
University of Washington
Andrew T. Bender
Affiliation:
University of Washington
Benjamin P. Sullivan
Affiliation:
University of Washington
Lorraine Lillis
Affiliation:
PATH Seattle
David S. Boyle
Affiliation:
PATH Seattle
Jonathan Posner
Affiliation:
University of Washington
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

OBJECTIVES/GOALS: Current COVID-19 rapid molecular tests require cartridge-reader detection, expensive circuitry, and complex microfluidics making the most accurate tests unavailable to the masses. Here we present a rapid molecular diagnostic leveraging isothermal amplification and paper-based microfluidics for a low-cost ultra-sensitive COVID-19 assay. METHODS/STUDY POPULATION: We designed a reverse transcription recombinase polymerase amplification (RT-RPA) assay for the detection of SARS-CoV-2 and bacteriophage MS2 RNA. RT-RPA is a sequence specific, ultrasensitive, rapid isothermal DNA amplification technique that is well suited to home based testing due to its rapid assay time, robustness, ease of use, and readout options. RT-RPA reagents are added to a tube and incubated at 39°C in a fluorometer. Realtime fluorometer data gives results in under 15 minutes. This assay also provides visual detection via lateral flow readout with results in 23 minutes. RESULTS/ANTICIPATED RESULTS: We have developed a rapid multiplexed nucleic acid amplification assay with an internal process control for SARS-CoV-2 using single-pot RT-RPA. We screened 21 primer combinations to select primers that demonstrated excellent performance and target specificity against common respiratory viruses. We demonstrate the ability to multiplex SARS-CoV-2 and MS2 detection, utilizing MS2 as an internal process control for lysis, reverse transcription, amplification, and readout. We show duplexed detection using both fluorescence readout and visual readout using lateral flow strips. Duplexed fluorescence detection shows a limit of detection of 25 copies per reaction. Duplexed lateral flow readout shows a limit of detection of 50 copies per reaction DISCUSSION/SIGNIFICANCE: We developed a duplexed RT-RPA assay for SARS-CoV-2 with fluorescence or lateral flow readout. Our assay does not re-quire expensive reader, circuity, or fluid handling. The low material cost, temperature, and robustness make it ideal for a more accurate home-based COVID-19 diagnostic.

Type
Other
Creative Commons
Creative Common License - CCCreative Common License - BYCreative Common License - NCCreative Common License - ND
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is unaltered and is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use or in order to create a derivative work.