Skip to main content Accessibility help
×
×
Home

Influence of switch level of automatic cluster removers on milking performance and udder health

  • Morten D. Rasmussen (a1)
Summary

The effect of a switch level of 200 or 400 g/min for automatic cluster removers on milking performance and udder health was measured with 71 first lactation cows in their first 36 weeks of lactation and with 64 older cows in their first 12 weeks of lactation. Early removal of the milking unit decreased machine-on time by 0·5 min, increased average milk flow rate slightly, improved teat condition significantly and reduced the change in teat end thickness during milking of first lactation cows. Early removal of the milking unit did not affect milk yield or composition, and the incidence and prevalence of subclinical mastitis were the same in the two groups. Fewer older cows developed clinical mastitis in the group switched at 400 g/min, but this was not significant. It is concluded that the milking unit can be detached at a milk flow rate of 400 instead of 200 g/min without having a negative influence on milk yield. Machine-on time is shortened and teat condition improved, and udder health does not seem to be affected.

Copyright
References
Hide All
Akam, D. N. 1989 Laboratory test methods for milking machine components. International Dairy Federation Bulletin Document 242 310
Anon. 1983 Instructions for mastitis laboratories. Danish State Veterinary Service, Copenhagen, DK
Berre, K. 1990 [Detachment time of automatic cluster removers.] Hovedopgave. Inst. Tekniske Fag, Norges Landbrukshøgskole, Ås 65 pp
Ebendorff, W., Kram, K., Ziesack, J., Hartmann, K. & M¨rchen, U. 1986 [The effects of omitting stripping on the milk yield and udder health of cows.] Monatshefte für Veterinärmedizin 41 189195
Gorewit, R. C. & Gassman, K. B. 1985 Effects of duration of udder stimulation on milking dynamics and oxytocin release. Journal of Dairy Science 68 18131818
Grindal, R. J. & Hillerton, J. E. 1991 Influence of milk flow rate on new intramammary infection in dairy cows. Journal of Dairy Research 58 263268
Hamann, J. 1989 Automatic cluster removers (ACR's). International Dairy Federation Bulletin Document 242 1113
Hamann, J. & Mein, G. A. 1988 Responses of the bovine teat to machine milking: measurements of changes in thickness of the teat apex. Journal of Dairy Research 55 331338
Mein, G. A. 1990 Forces applied to the teat: conventional milking. Proceedings Symposium Machine Miliking and Mastitis. Koldkaergaard, Aarhus, DK6173
Mein, G. A., Brown, M. R. & Williams, D. M. 1986 Effects on mastitis of overmilking in conjunction with pulsation failure. Journal of Dairy Research 53 1722
Natzke, R. P. 1978 The relationship between overmilking and new infection. Proceedings Annual Meeting National Mastitis Council 17 256261
Østerås, O. & Lund, A. 1988 Epidemiological analyses of the associations between bovine udder health and milking machine and milking management. Preventive Veterinary Medicine 6 91108
Rasmussen, M. D. 1992 The influence of switch level of automatic cluster removers on milking performance and udder health. In International Symposium on Prospects for Automatic Milking, Wageningen, pp. 113118. (EAAP Publication 65)
Rasmussen, M. D., Frimer, E. S., Horvath, Z. & Jensen, N. E. 1990 Comparison of a standardized and variable milking routine. Journal of Dairy Science 73 34723480
Sagi, R. 1978 Milk flow rate and end of milking detectors. Proceedings Annual Meeting National Mastitis Council 17 328334
SAS 1985 Sas Users' Guide: Statistics, Cary, NC: SAS Institute
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Journal of Dairy Research
  • ISSN: 0022-0299
  • EISSN: 1469-7629
  • URL: /core/journals/journal-of-dairy-research
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed