Hostname: page-component-76fb5796d-vfjqv Total loading time: 0 Render date: 2024-04-26T09:44:36.484Z Has data issue: false hasContentIssue false

Analysis and Optimisation of New Implantation and Activation Mechanisms in Ultra Shallow Junction Implants using Scanning Spreading Resistance Microscopy (SSRM)

Published online by Cambridge University Press:  01 February 2011

Pierre Eyben
Affiliation:
eyben@imec.be, IMEC, SPDT/MCA, Kapeldreef 75, Leuven, N/A, B3001, Belgium
Simone Severi
Affiliation:
Simone.Severi@imec.be, IMEC, SPDT/DIP, Kapeldreef 75, Leuven, N/A, B3001, Belgium
Ray Duffy
Affiliation:
Ray.Duffy@imec.be, Philips Research Europe, Kapeldreef 75, Leuven, N/A, B3001, Belgium
Bartek Pawlak
Affiliation:
Bartek.Pawlak@imec.be, Philips Research Europe, Kapeldreef 75, Leuven, N/A, B3001, Belgium
Emmanuel Augendre
Affiliation:
Emmanuel.Augendre@imec.be, IMEC, SPDT/DIP, Kapeldreef 75, Leuven, N/A, B3001, Belgium
Wilfried Vandervorst
Affiliation:
Wilfried.Vandervorst@imec.be, IMEC, SPDT/MCA, Kapeldreef 75, Leuven, N/A, B3001, Belgium
Get access

Abstract

Within this paper we have demonstrated the unique capability of scanning spreading resistance microscopy (SSRM) in order to evaluate and optimize the recent approaches towards the formation of advanced p-MOS devices. As shown in this paper, such an optimization requires a detailed 2D-analysis on completely processed devices as two-dimensional interactions may cause (unexpected) lateral diffusion and (de) activation of underlying profiles. Emphasis will be on junction formation using Ge- pre-amorphization and carbon based cocktail implantation coupled with activation based on solid phase epitaxial regrowth and/or millisecond laser anneal. In the case of a Ge-pre-amorphization implant followed by solid phase epitaxial regrowth, SSRM shows an obvious relationship between the presence of defects in the end of range region and halo implant de-activation. Based on the quantified 2D-profiles we can extract the lateral and vertical junction depths as well as the lateral and vertical abruptness of the extension region. A drastic reduction of the lateral diffusion for the cocktail implant versus the standard reference devices with classical spike annealing is eminent. At the same an important reduction of the lateral diffusion of the source/drain implants (HDD) under the spacer can be seen. The SSRM results also highlight the impact of different activation mechanisms on the channel implants (in particular on the shape of the halo pockets).

Type
Research Article
Copyright
Copyright © Materials Research Society 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Moroz, V. et al, Appl. Phys. Lett., vol.87, p.051908, 2005.Google Scholar
2 Osburn, C. M. et al, Ion Implantation Tech., p.832, 1996.Google Scholar
3 Tsuji, K. et al, IEDM Tech Dig, p.9, 1999.Google Scholar
4 Severi, S. et al, Proc. ULIS 2004, Leuven, p.69, 2004.Google Scholar
5 Jain, S. H. et al, IEEE Trans. on Elec. Dev., vol. 52, Num. 7, 2005.Google Scholar
6 Shima, A. et al, IEEE Trans. on Elec. Dev, vol.52, Num.6, 2005.Google Scholar
7 Wolf, P. De et al, J. Vac. Sci. Technol. B14, p.380, 1996.Google Scholar
8 Eyben, P., Janssens, T. and Vandervorst, W., Mat. Sci. & Eng. B, vol.124–125, p.45, 2005.Google Scholar
9 Wolf, P. De, Clarysse, T., and Vandervorst, W., J. Vac. Sci. Technol. B16(1), p.320, 1998.Google Scholar
10 Eyben, P. et al, AIP Conf. Proc. 683, p.685, 2003.Google Scholar
11 Hantschel, T. et al, Micr. Eng., vol.57–58, p.749, 2001.Google Scholar
12 Fouchier, M. et al, Proc. of SPIE 5116, p.607, 2003.Google Scholar
13 Lindsay, R. et al, Proc. Mat. Res. Soc. Symp. D, vol.765, 2003.Google Scholar
14 Severi, S., et al, Proc. IEDM, 2004.Google Scholar
15 Pawlak, B. et al, Submitted to APL.Google Scholar
16 Eyben, P. et al, J. Vac. Sci. Technol. B 20(1) p.471, 2002 Google Scholar