Application of Z-Contrast Imaging to Obtain Column-by-Column Spectroscopic Analysis of Materials

Published online by Cambridge University Press:  15 February 2011

Nigel D. Browning
Affiliation:
Solid State Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030
Stephen J. Pennycook
Affiliation:
Solid State Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030
Get access

Abstract

Z-contrast imaging has been shown to be an effective method for obtaining a highresolution image from a scanning transmission electron microscope (STEM). The incoherent nature of the high-angle scattering makes image interpretation straightforward and intuitive with the resolution limited only by the 2.2 Å electron probe. The optimum experimental conditions for Z-contrast imaging also coincide with those used for analytical microscopy, enabling microanalysis to be performed with the same spatial resolution as the image. The detection limits afforded by a parallel detection system for electron energy loss spectroscopy (EELS) allows column-by-column core-loss spectroscopy to be performed using the Z-contrast image to position the electron probe. Preliminary results from the study of Yba2Cu3O7-δ illustrate the spatial resolution available with this technique and the potential applications for materials science.

Type
Research Article
Copyright
Copyright © Materials Research Society 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Pennycook, S. J. and Jesson, D. E, Phys. Rev. Lett. 64, 938 (1990).Google Scholar
2. Brown, L. M., J. Phys. F 11, (1981).Google Scholar
3. Colliex, C. and Mory, C., Quantitative Electron Microscopy, Chapman, J. N. and Craven, A. J., eds., SUSSP Publications, Edinburgh, 1984, pp 149216.Google Scholar
4. Pennycook, S. J. and Jesson, D. E., Ultramicroscopy 37, 14 (1991).Google Scholar
5. Scherzer, O., J. Appl. Phys 20, 20 (1949).Google Scholar
6. Ritchie, R. H. and Howie, A., Philos. Mag. 58, 753 (1988).Google Scholar
7. Allen, L. J. and Rossouw, C. J., Phys. Rev. B 42, 11644 (1990).CrossRefGoogle Scholar
8. Pennycook, S. J., Contemp. Phys. 23, 371 (1982).Google Scholar
9. Collett, S. A., Brown, L. M. and Jacobs, M. H., Inst. Phys. Conf. Ser. 68, 103 (1984).Google Scholar
10. Isaacson, M. and Johnson, D., Ultramicroscopy 1, 33 (1975).CrossRefGoogle Scholar
11. Furdanowicz, W. A., Garratt-Reed, A. J. and Vander Sande, J. B., Inst. Phys. Conf. Ser. 119, 437 (1991).Google Scholar