Hostname: page-component-76fb5796d-zzh7m Total loading time: 0 Render date: 2024-04-29T08:03:06.263Z Has data issue: false hasContentIssue false

Detection of Residual Stress in Silicon Carbide MEMS by μ-Raman Spectroscopy

Published online by Cambridge University Press:  01 February 2011

John C. Zingarelli
Affiliation:
Department of Engineering Physics, Air Force Institute of Technology Wright-Patterson AFB OH 45433-7765
Michael A. Marciniak
Affiliation:
Department of Engineering Physics, Air Force Institute of Technology Wright-Patterson AFB OH 45433-7765
Jason R. Foley
Affiliation:
Munitions Directorate, Air Force Research Laboratory Eglin AFB FL 32542-5430
Get access

Abstract

Micro-Raman (μ-Raman) spectroscopy is used to measure residual stress in single-crystal, 6H-silicon carbide (SiC) used in micro-electro-mechanical-systems (MEMS) devices. These structures are bulk micro-machined by back etching a 250-μm-thick, single-crystal 6HSiC wafer (p-type, 7 Ω-cm, 3.5° off-axis) to form a 50-μm thick diaphragm. A Wheatstone bridge, patterned of piezoresistive elements, is formed across the membrane from a 5-μm, 6HSiC (n-type, doped 3.8 × 1018 cm-3) epilayer; the output of the bridge is proportional to the flexure of the MEMS diaphragm. For these samples, the μ-Raman spectroscopy is performed using a Renishaw InVia Raman spectrometer with an argon-ion excitation source (λ = 514.5 nm, hν = 2.41 eV) with an approximate 1-μm2 spot size through the 50X objective. By employing an incorporated piezoelectric stage with submicron positioning capabilities along with the Raman spectral acquisition, spatial scans are performed to reveal areas in the MEMS structures that contain residual stress. Shifts in the transverse optical (TO) Stokes peaks of up to 2 cm-1 along the edge of the diaphragm and through the piezoresistors indicate significant material strain induced by the MEMS fabrication process.

The phonon deformation potential is measured to quantify the material stress as a function of the shift in the Raman peak position. The line center of the TO Stokes peak is shifted by applying a uniform stress to the sample and monitoring the applied stress using a strain gauge, while the μ-Raman spectrum is being measured. A spectral analysis code tracks the shift of the Raman peak position with respect to the line center of the Rayleigh peak to account for any thermal drift of the spectrometer during the time of the area scan.

Type
Research Article
Copyright
Copyright © Materials Research Society 2005

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Zorman, C.A. and Mehregany, M., “Silicon carbide for MEMS and NEMS - an overview,” Sensors 2002, Proceedings of IEEE 2, 1109 (2002).Google Scholar
2 Melzak, J.M., “Silicon carbide for RFMEMS,” Microwave Symposium Digest, 2003 IEEE MTT-S International 3, 1629 (2003).Google Scholar
3 Mehregany, M., Zorman, C.A., Rajan, N., and Wu, C.H., “Silicon carbide MEMS for harsh environments,” IEEE 86, 1594 (1998).Google Scholar
4 Inc, Cree, Silicon Carbide Substrates, 1998. Product Specifications: 4H Silicon Carbide (n/p-type, Semi-Insulating); 6H Silicon Carbide (n/p-type).Google Scholar
5 Brink, D.J., Maurice, T., Blanque, S., Kunert, H., Camassel, J., and Pascul, J., “Depth profiling of high-energy hydrogen-implanted 6H-SiC,” Applied Optics 43, 1275 (2004).Google Scholar
6 Liu, J. and Vohra, Y. K., “Raman modes of 6H poly-type of silicon carbide to ultrahigh pressures: A comparison with silicon and diamond,” Physical Review Letters 72, 4105 (1994).Google Scholar
7 Milton, J.S. and Arnold, J.C., Introduction to Probability and Statistics Principles and Application for Engineering and the Computing Sciences. New York, New York: McGraw Hill, 2003.Google Scholar