Skip to main content
×
×
Home

Electrochemical Deposition and Evaluation of Conductive Polymer Coating on Biodegradable Magnesium Implants for Neural Applications

  • Meriam A. Sebaa (a1), Shan Dhillon (a1) and Huinan Liu (a1) (a2)
Abstract

In an attempt to develop conductive, biodegradable, mechanically strong, and biocompatible nerve conduits, pure magnesium (Mg) was used as the biodegradable substrate material to provide strength while the conductive polymer, poly(3,4ethylenedioxythiophene) (PEDOT) was used as a conductive coating material to control Mg degradation and improve cytocompatibility of Mg substrates. This study explored a series of electrochemical deposition conditions to produce a uniform, consistent PEDOT coating on Mg substrates. The microstructure and morphology of the coating and Mg were visualized using scanning electron microscopy (SEM). The elemental composition of the surface was quantified using energy dispersive X-ray spectroscopy (EDS). Adhesion strength of the coating was measured using the tape test following the ASTM-D 3359 standard. The SEM results showed uniform and consistent PEDOT coating, and EDS analysis confirmed the elemental composition of PEDOT. The adhesion strength of PEDOT coating was within the classifications of 3B to 4B.

Copyright
Corresponding author
#corresponding to huinan.liu@ucr.edu
Footnotes
Hide All
*

Equally contributed;

Footnotes
References
Hide All
1. Muir, K.W., New experimental and clinical data on the efficacy of pharmacological magnesium infusions in cerebral infarcts. Magnesium Research, 1998. 11(1): p. 4356.
2. Clarkson, A.N., Anesthetic-mediated protection/preconditioning during cerebral ischemia. Life Sciences, 2007. 80(13): p. 11571175.
3. Gupta, V.K., Intravenous magnesium for neuroprotection in acute stroke: Clinical hope versus basic neuropharmacology. Stroke, 2004. 35(12): p. 27582758.
4. Saver, J.L., et al. ., Prehospital neuroprotective therapy for acute stroke - Results of the field administration of stroke therapy-magnesium (FAST-MAG) pilot trial. Stroke, 2004. 35(5): p. E106-E108.
5. Campbell, K., et al. ., Magnesium treatment and spontaneous mild hypothermia after transient focal cerebral ischemia in the rat. Brain Research Bulletin, 2008. 77(5): p. 320322.
6. Kohno, H., et al. ., Three-day magnesium administration prevents atrial fibrillation after coronary artery bypass grafting. Annals of Thoracic Surgery, 2005. 79(1): p. 117126.
7. Waligorski, S., et al. ., Assessment of the role of magnesium supplementation in prevention of atrial fibrillation in patients after coronary bypass grafting operations. Kardiochirurgia I Torakochirurgia Polska, 2010. 7(2): p. 141145.
8. Zhang, S.X., et al. ., Research on an Mg-Zn alloy as a degradable biomaterial. Acta Biomaterialia, 2010. 6(2): p. 626640.
9. Witte, F., et al. ., Degradable biomaterials based on magnesium corrosion. Current Opinion in Solid State & Materials Science, 2008. 12(5-6): p. 6372.
10. Richardson-Burns, S.M., et al. ., Polymerization of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) around living neural cells. Biomaterials, 2007. 28(8): p. 15391552.
11. Luo, S.C., et al. ., Poly(3,4-ethylenedioxythiophene) (PEDOT) nanobiointerfaces: Thin, ultrasmooth, and functionalized PEDOT films with in vitro and in vivo biocompatibility. Langmuir, 2008. 24(15): p. 80718077.
12. Cui, X.Y. and Martin, D.C., Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays. Sensors and Actuators B-Chemical, 2003. 89(1-2): p. 92102.
13. Yang, J.Y. and Martin, D.C., Microporous conducting polymers on neural microelectrode arrays II. Physical characterization. Sensors and Actuators a-Physical, 2004. 113(2): p. 204211.
14. Cui, X.Y.T. and Luo, X.L., Electrochemical deposition of conducting polymer coatings on magnesium surfaces in ionic liquid. Acta Biomaterialia, 2011. 7(1): p. 441446.
15. Tamburri, E., et al. ., Study of PEDOT conductive polymer films by admittance measurements. Materials Chemistry and Physics, 2011. 125(3): p. 397404.
16. Chandrasekhar, P., ed. Conducting Polymers Fundamentals and Applications. 1999, Springer.
17. Peter, J Blau, K.G.B., Development and use of ASTM standards for wear testing. Wear 1999. 225-229(part 2): p. 11591170.
18. Takuma Muto, M.I., Kobayashi, Koichi, Miyasaka, Tsutomu, Conductive Polymer-based Mesoscopic Counterelectrodes for Plastic Dye-sensitized Solar Cells. Chemistry Letters, 2007. 36(6): p. 804805.
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

MRS Online Proceedings Library (OPL)
  • ISSN: -
  • EISSN: 1946-4274
  • URL: /core/journals/mrs-online-proceedings-library-archive
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed