High-Dielectric-Constant All-Organic/Polymeric Composite Actuator Materials

Published online by Cambridge University Press:  01 February 2011

Cheng Huang
Affiliation:
Materials Research Institute and Electrical Engineering Department, The Pennsylvania State University, University Park, PA 16802
Ji Su
Affiliation:
Advanced Materials and Processing Branch, NASA Langley Research Center, Hampton, VA 23681
Q.M. Zhang
Affiliation:
Materials Research Institute and Electrical Engineering Department, The Pennsylvania State University, University Park, PA 16802
Get access

Abstract

Among various electroactive polymer (EAP) actuator materials developed recently, the class of EAPs whose responses are stimulated by external electrical fields (often known as the field type EAPs) is especially attractive due to their high strain level and elastic energy density. However, for most field type EAPs, dielectric constant is low, generally less than 10. Consequently, these polymers usually require high electric fields (>100 V/μm) to generate high elastic energy density which limits their applications. In this paper, we will investigate some avenues to significantly raise the dielectric constant and electromechanical response in field type polymeric materials. By exploiting an all-organic composite approach in which high-dielectric-constant organic particulates were blended with a polymer matrix, a polymeric-like material can reach a dielectric constant higher than 400, which results in a significant reduction of the applied field to generate high strain with high elastic energy density. An all-polymer high-dielectric-constant (K>1,000 @1 kHz) percolative composite material was fabricated by the combination of conductive polyaniline particles (K>105) within a fluoroterpolymer matrix (K>50). These high-K polymer hybrid materials also exhibit high electromechanical responses under low applied fields. In addition, a three-component all-organic composite was designed and prepared to improve the dielectric constant and the electromechanical response, as well as the stability of the composites, in which a high-dielectric-constant organic dielectric phase and an organic conductive phase were embedded into the soft dielectric elastomer matrix.

Type
Research Article
Copyright
Copyright © Materials Research Society 2004

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Bar-Cohen, Y. (ed.), Electroactive Polymer Actuators as Artificial Muscles, (SPIE, Bellingham, WA, 2001);Google Scholar
Zhang, Q.M., Furukawa, T., Bar-Cohen, Y. and Scheinbeim, J. (eds.), Electroactive Polymers (EAPs), (Mater. Res. Soc. Proc. Warrendale, PA, 600, 1999 & 698, 2001); http://ndeaa.jpl.nasa.gov/nasa-nde/lommas/eap/EAP-web.htm.Google Scholar
2. Nalwa, H. (ed.), Handbook of Low and High Dielectric Constant Materials and Their Applications, (Academic, London, 1999); Handbook of Advanced Electronic and Photonic Materials and Devices, (Academic, London, 2001).Google Scholar
3. Xu, T.-B., Cheng, Z.-Y. and Zhang, Q.M., Appl. Phys. Lett. 80, 1082, (2002).10.1063/1.1448661Google Scholar
4. Xia, F., Xu, T.-B., Huang, C., Tadigadapa, S. and Zhang, Q.M., ACS Polym. Prep. (2003).Google Scholar
5. Galletti, P.M., De Rossi, D.E. and De Reggi, A.S. (eds.), Medical Applications of Piezoelectric Polymers (Gordon & Breach, New York, 1988).Google Scholar
6. Zhang, Q.M., Li, H., Poh, M., Xia, F., Cheng, Z.-Y., Xu, H. and Huang, C., Nature 419, 284, (2002).10.1038/nature01021Google Scholar
7. Zhang, Q.M. and Huang, C., US Provisional Patent Filed.Google Scholar
8. Zhang, Q.M., Bharti, V. and Zhao, X., Science 280, 2101 (1998).10.1126/science.280.5372.2101Google Scholar
9. Xu, H., Cheng, Z.-Y., Olson, D., Mai, T., Zhang, Q.M. and Kavarnos, G., Appl. Phys. Lett. 78, 2360 (2001).10.1063/1.1358847Google Scholar
10. Su, J., Moses, P. and Zhang, Q.M., Rev. Sci. Instrum. 69, 2480 (1998).10.1063/1.1148947Google Scholar
11. Huang, C., Klein, R., Xia, F., Li, H., Zhang, Q.M., Bauer, F. and Cheng, Z.-Y., IEEE Trans. Diel. & Elec. Insu. Dec. (2003).Google Scholar
12. Bobnar, V., Levstik, A., Huang, C. and Zhang, Q.M., Phys. Rev. Lett. (submitted).Google Scholar
13. Huang, C., Zhang, Q.M. and Su, J., Appl. Phys. Lett. 82, 3502 (2003).10.1063/1.1575505Google Scholar
14. Huang, C. and Zhang, Q.M., Adv. Funct. Mater. (in press).Google Scholar
15. Su, J., Zhang, Q.M. and Ting, R.Y., Appl. Phys. Lett. 71, 386 (1997).10.1063/1.119545Google Scholar
16. Li, J.Y. and Rao, N., Appl. Phys. Lett. 81, 1860 (2002).10.1063/1.1505743Google Scholar
17. Li, J.Y., Phys. Rev. Lett. 90, 217601 (2003).10.1103/PhysRevLett.90.217601Google Scholar