Hostname: page-component-7bb8b95d7b-495rp Total loading time: 0 Render date: 2024-09-26T17:24:48.611Z Has data issue: false hasContentIssue false

Infrared Microspectroscopy Mapping Techniques for The Analysis of Cross Sections and As Anon-Destructive Analysis Method for Paint on A Manuscript

Published online by Cambridge University Press:  26 February 2011

Michele R. Derrick*
Affiliation:
Getty Conservation Institute, Marina del Rey, CA, USA
Get access

Abstract

Infrared microspectroscopy is useful for characterizing media in very small cross sectionsamples using both transmission and reflection modes of analysis. In a direct comparison of the two methods, reflection techniques produce poorer quality spectra than the transmission methods. However, many of the problems of reflection spectra can be mitigated by looking at the variations that occur between spectra obtained under similar conditions. An excellent venue for such a study is the use of infrared mapping. Mapping studies compare the intensities of absorption bands versus their location in the sample to generate an image of compositional differences in a region. Several examples are shown in this paper for the application of infrared mapping to the determination of components in thin section and cross section samples. The technique for infrared mapping was also used as a direct, nondestructive method for the characterization of colorants and binders on a small painted manuscript leaf. Compared to the paint cross sections, four relatively large areas (1 cm2) were mapped with the infrared microscope then joined together using a mosaic technique.

Type
Research Article
Copyright
Copyright © Materials Research Society 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Baker, M., Endt, D. von, Hopwood, W. and Earhardt, D., AIC preprints, 16th annual meeting, New Orleans, Louisiana, 1 (1988).Google Scholar
2. Tsang, J., and Cunningham, R., JAIC, 30(2), 163 (1991).Google Scholar
3. Derrick, M.R., Stulik, D.C., Landry, J.M. and Bouffard, S.P., JAIC, 31(2), 225 (1992).Google Scholar
4. Katon, J.E., Sommer, A.J. and Lang, P.L., App. Spec. Rev., 25(3), 173 (1989).Google Scholar
5. Harthcock, M.A., and Atkin, S.C., in Infrared Microspectroscopy. edited by Messerschmidt, R.G. and Harthcock, M.A. (Marcel Dekker, New York 1988) pp.2140.Google Scholar
6. Derrick, M., Doehne, E., Parker, A. and Stulik, D., JAIC, 33 (1994).Google Scholar
7. Brodsky-Doyle, B., Bendi, E.G. and Blout, E.R., Biopolymers, 14 937 (1975).Google Scholar
8. Susi, H., Ard, J.S., and Carroll, R.J., J. Am. Leather Chem. Assoc., 66(11), 508 (1975).Google Scholar
9. Warren, J.R., Smith, W.E. and Tillman, W.J., J. Am. Leather Chem. Assoc., 64, 4 (1969).Google Scholar