Hostname: page-component-8448b6f56d-sxzjt Total loading time: 0 Render date: 2024-04-23T09:13:45.587Z Has data issue: false hasContentIssue false

Massively Parallel Scanning Probes Microscope with Digital Holographic Readout

Published online by Cambridge University Press:  01 February 2011

Laurent Sache
Affiliation:
laurent.sache@epfl.ch, EPFL, LSRO, EPFL - LSRO1, Station 9, Lausanne, 1015, Switzerland
Hannes Bleuler
Affiliation:
hannes.bleuler@epfl.ch, EPFL - LSRO, Lausanne, 1015, Switzerland
Get access

Abstract

Massively Parallel Scanning Probe Microscopy is an obvious path for enhancing the acquisition speed and the imaging range of current based-AFM metrology devices. Current experimental systems, based on active probes array, would reach their limits in density and hardware complexity. This paper presents a new approach with the promise to break several of these barriers. The key idea is readout of a Scanning Probes Microscope (SPM) array by an interferometer technique called digital holography which directly gives the cantilever phase information at each pixel of a CCD array. This means that no contact line to each individual SPM probes is needed, allowing us to reach very high density of probes. The phase information is available in a parallel form in real-time. Moreover, the digital holography optical setup (Digital Holography Microscope or DHM) needs in principle no expensive components, optical (or, to a large extent, mechanical) imperfections being compensated in the signal processing, i.e. in electronics. This gives the system the potential for a low cost device with fast and large readout capability.

Type
Research Article
Copyright
Copyright © Materials Research Society 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Minne, S.C., Adams, J. D., Yaralioglu, G., Manalis, S. R., Atalar, A. and Quate, C. F., “Centimeter scale atomic force microscope imaging and lithography”, Applied Physics Letters, 1998, 73, 12, 17421744.Google Scholar
2. Tao, Y., Fasching, R. J. and Prinz, F. B., “Ultra-sharp High-aspect-ratio Probe Array for SECM and AFM Analysis”, in SPIE Proceedings: Smart Structures and Materials Conference 2005.Google Scholar
3. Cuche, E., Marquet, P. and Depeursinge, C., "Simultaneous amplitude and quantitative phasecontrast microscopy by numerical reconstruction of Fresnel off-axis holograms", Appl. Opt., 1999, 38, 69947001.10.1364/AO.38.006994Google Scholar
4. Goodman, J.W. and Lawrence, R.W., "Digital image formation from electronically detected holograms", Apply physics letter, 1967, 11, 7779.Google Scholar