Hostname: page-component-76fb5796d-wq484 Total loading time: 0 Render date: 2024-04-26T18:34:35.613Z Has data issue: false hasContentIssue false

Morphological and Structural Evolution of an Ultra-low-k Dielectric During the Porogen Removal

Published online by Cambridge University Press:  01 February 2011

Diane Rebiscoul
Affiliation:
diane.rebiscoul@cea.fr, CEA, LETI, 17 rue des Martyrs, Grenoble, France, 38054, France, 33 4 38 78 10 59, 33 4 38 78 30 34
Héléne Trouvé
Affiliation:
htrouve@rohmhass.com, Rohm and Haas Electronic Material LLC, Grenoble, France, 38054, France
Bruno Remiat
Affiliation:
bruno.remiat@cea.fr, CEA, LITEN, 17 rue des Martyrs, Grenoble, Isere, 38054, France
Laurence Clerc
Affiliation:
laurence.clerc@cea.fr, CEA, LETI, 17 rue des martyrs, Grenoble, Isere, 38054, France
Didier Louis
Affiliation:
didier.louis@cea.fr, CEA, LETI, 17 rue des martyrs, Grenoble, Isere, 38 054, France
Gerard Passemard
Affiliation:
gerard.passemard@cea.fr, STmicroelectronic, LETI, 17 rue des Martyrs, Grenoble, Isere, 38054, France
Get access

Abstract

The use of porous ultra-low-k materials between interconnections for sub 45nm technologies has introduced some barrier diffusion and mechanical problems. In order to avoid the problems caused by the porosity, a hybrid dense material (porogen and matrix) can be used in an alternate integration scheme. In this approach, the porogen is removed after CMP steps by a thermal cure or UV assisted thermal cure. In this work, we have first characterized the impact of the temperature and the duration of the thermal cure on the material. The crosslinking degree increases and the porogen amount decreases with increasing cure temperature. The most important impact of the curing duration happens between 350°C and 400°C. The increase of the curing duration leads to an increase of the porogen loss and a decrease of the refractive index. Secondly, in order to assess the structure of the layer as a function of the depth, the material was etched in a 0.05% HF solution and then characterized. According to the temperature and duration of the cure, the etch-rate can vary as a function of the material depth. This variation is related to a complex gradient inside the material.

Type
Research Article
Copyright
Copyright © Materials Research Society 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Maîtrejean, S., Houziaux, X., Fayolle, M., et al, Admeta, Tokyo, Mat. Res. Soc. Symp. Proc., 2005, accepted.Google Scholar
2 Verdier, M., Montagna, M., Maitrejean, S., Passemard, G., Mater. Res. Soc. Symp. Proc. 795 (2004) 1.Google Scholar
3 Chérault, N., Carlotti, G., Casanova, N., Gergaud, P., et al, to be published in Microelec. Eng (2005).Google Scholar
4 Leduc, P., Savoye, M., Maitrejean, S., Scevola, D., Jousseaume, V., Passemard, G., Proc. of the IITC, 2005.Google Scholar
5 Jousseaume, V., Assous, M., Zenasni, A., Maitrejean, S., Remiat, B., et al, Proceedings of the IEEE 2005 International Interconnect Technology Conference (2005) 6062.Google Scholar
6 Jousseaume, V., Beynet, J., Remiat, B., Gaillard, F., Lumia, G., Didier, G. et al, Proc. of Advanced Metallization Conference, (2005) accepted.Google Scholar
7 Lee, A. Van der, Solid State Sciences, 2 (2) 2000, 257278 Google Scholar
8 Chang, S. Y., Chou, T-J, Lu, Y-C., et al, J. Electrochem. Soc. 151 (2004), 146.Google Scholar
9 Rebiscoul, D., Puyrenier, B., Broussous, L., et al, Micro. Elec. Eng., (2006) submitted.Google Scholar