Hostname: page-component-8448b6f56d-42gr6 Total loading time: 0 Render date: 2024-04-25T01:19:06.255Z Has data issue: false hasContentIssue false

Particle and UV-Imaging with Position Sensitive MCP-Detectors-Three-Dimensional Momentum Space Imaging

Published online by Cambridge University Press:  10 February 2011

V. Mergel
Affiliation:
Institut für Kernphysik, Johann Wolfgang Goethe-Universität, August-Euler-Str. 6, D-60486 Frankfurt, Germany
O. Jagutzki
Affiliation:
Institut für Kernphysik, Johann Wolfgang Goethe-Universität, August-Euler-Str. 6, D-60486 Frankfurt, Germany
L. Spielberger
Affiliation:
Institut für Kernphysik, Johann Wolfgang Goethe-Universität, August-Euler-Str. 6, D-60486 Frankfurt, Germany
K. Ullmann-Pfleger
Affiliation:
Institut für Kernphysik, Johann Wolfgang Goethe-Universität, August-Euler-Str. 6, D-60486 Frankfurt, Germany
R. Dörner
Affiliation:
Institut für Kernphysik, Johann Wolfgang Goethe-Universität, August-Euler-Str. 6, D-60486 Frankfurt, Germany
H. Schmidt-Böcking
Affiliation:
Institut für Kernphysik, Johann Wolfgang Goethe-Universität, August-Euler-Str. 6, D-60486 Frankfurt, Germany
Get access

Abstract

Various position sensitive microchannel-plate (MCP) detector systems for ion, electron and photon detection are presented. We have also developed a complete set of electronics to operate the detectors and software to analyze the incoming data. The detectors provide two-dimensional position as well as excellent timing information, e.g. for time-of-flight measurements. All data can be stored in single event mode. These MCP-detectors were used for electron and ion analyzers, which provide a three-dimensional imaging of the momentum space of all detected particles.

Type
Research Article
Copyright
Copyright © Materials Research Society 1998

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1 Some examples for such detectors are our ears or eyes, telescopes or photographic films.Google Scholar
2 Fraser, G. W., Nucl. Instr. Meth. 221:115, 1984.Google Scholar
3 Wiza, J. L., Nucl. Instr. Meth. B162:587, 1979.Google Scholar
4 For some wavelenghts of light an additional photocathode may increase the efficiency.Google Scholar
5 Fa. Roentdek GmbH, Kelkheim Germany.Google Scholar
6 Sobottka, S. E. and Williams, M. B., IEEE Trans. Nucl. Science 35:348, 1988.Google Scholar
7 Nüttgens, S., Diploma-thesis, 1994, I. Ali, PhD-thesis, 1997, both University Frankfurt.Google Scholar
8 Ullrich, J and Moshammer, R., private communications, 1997.Google Scholar
9 Eland, J. H. D., Meas. Sci. Technol. 5:1501, 1994.Google Scholar
10 Mergel, V., PhD-thesis, University Frankfurt, ISBN 3–8265-2067-X, 1996.Google Scholar