Integration of Energy Analytics and Smart Energy Microgrid into Mobile Medicine Operations for the 2012 Democratic National Convention

  • Peter W. McCahill (a1), Erin E. Noste (a1), AJ Rossman (a2) and David W. Callaway (a1)
Abstract
Introduction

Disasters create major strain on energy infrastructure in affected communities. Advances in microgrid technology offer the potential to improve “off-grid” mobile disaster medical response capabilities beyond traditional diesel generation. The Carolinas Medical Center's mobile emergency medical unit (MED-1) Green Project (M1G) is a multi-phase project designed to demonstrate the benefits of integrating distributive generation (DG), high-efficiency batteries, and “smart” energy utilization in support of major out-of-hospital medical response operations.

Methods

Carolinas MED-1 is a mobile medical facility composed of a fleet of vehicles and trailers that provides comprehensive medical care capacities to support disaster response and special-event operations. The M1G project partnered with local energy companies to deploy energy analytics and an energy microgrid in support of mobile clinical operations for the 2012 Democratic National Convention (DNC) in Charlotte, North Carolina (USA). Energy use data recorded throughout the DNC were analyzed to create energy utilization models that integrate advanced battery technology, solar photovoltaic (PV), and energy conservation measures (ECM) to improve future disaster response operations.

Results

The generators that supply power for MED-1 have a minimum loading ratio (MLR) of 30 kVA. This means that loads below 30 kW lead to diesel fuel consumption at the same rate as a 30 kW load. Data gathered from the two DNC training and support deployments showed the maximum load of MED-1 to be around 20 kW. This discrepancy in MLR versus actual load leads to significant energy waste. The lack of an energy storage system reduces generator efficiency and limits integration of alternative energy generation strategies. A storage system would also allow for alternative generation sources, such as PV, to be incorporated. Modeling with a 450 kWh battery bank and 13.5 kW PV array showed a 2-fold increase in potential deployment times using the same amount of fuel versus the current conventional system.

Conclusions

The M1G Project demonstrated that the incorporation of a microgrid energy management system and a modern battery system maximize the MED-1 generators’ output. Using a 450 kWh battery bank and 13.5 kW PV array, deployment operations time could be more than doubled before refueling. This marks a dramatic increase in patient care capabilities and has significant public health implications. The results highlight the value of smart-microgrid technology in developing energy independent mobile medical capabilities and expanding cost-effective, high-quality medical response.

McCahill PW , Noste EE , Rossman AJ , Callaway DW . Integration of Energy Analytics and Smart Energy Microgrid into Mobile Medicine Operations for the 2012 Democratic National Convention. Prehosp Disaster Med. 2014;29(6):1-8 .

Copyright
Corresponding author
Correspondence: Peter W. McCahill, MD Carolinas Medical Center Department of Emergency Medicine 1000 Blythe Blvd. Charlotte, North Carolina 28203 USA E-mail pmccahill@gmail.com
References
Hide All
1. Neuman, S. Superstorm Shines A Light On Power Grid Vulnerabilities. NPR, the two-way Web site. http://www.npr.org/blogs/thetwo-way/2012/10/30/163970272/superstorm-shines-a-light-on-power-grid-vulnerabilities. Published October 30, 2012. Accessed April 22, 2014.
2. Domm, P. Why East Coast Gas Shortages May Not End for a Week. CNBC Web site. http://www.cnbc.com/id/49642174. Published November 1, 2012. Accessed April 22, 2014.
3. Blackwell, T, Bosse, M. Use of an innovative design mobile hospital in the medical response to Hurricane Katrina. Ann Emerg Med. 2007;49(5):580-588.
4. Bernal-Agustín, JL, Dufo-López, R. Simulation and optimization of stand-alone hybrid renewable energy systems. Renewable and Sustainable Energy Reviews. 2009;13(8):2111-2118.
5. Anderson, GB, Bell, ML. Lights out: impact of the August 2003 power outage on mortality in New York, NY. Epidemiology. 2012;23(2):189-193.
6. Lin, S, Fletcher, BA, Luo, M, Chinery, R, Hwang, SA. Health impact in New York City during the Northeastern blackout of 2003. Public Health Rep. 2011;126(3):384-393.
7. Powell, T, Hanfling, D, Gostin, L. Emergency preparedness and public health: the lessons of Hurricane Sandy. JAMA. 2012;308(24):2569-2570.
8. Redlener, I, Reilly, MJ. Lessons from Sandy – preparing health systems for future disasters. NEJM. 2012;376(24):2269-2271.
9. Wood, D. As Sandy's Fuel Crisis Eases, FEMA Gassing Up Only Emergency Vehicles. Huffington Post Web site. http://www.huffingtonpost.com/2012/11/05/sandy-fuel-shortage-fema-gasoline_n_2079218.html. Published November 5, 2012. Accessed April 22, 2014.
10. Mathias, JM. Surgery by flashlight as Joplin team operates through tornado. OR Manager. 2011;27(7):6-7.
11. Young, W. History of Applying Photovoltaics to Disaster Relief. Florida Solar Energy Center/University of Central Florida. http://www.fsec.ucf.edu/en/publications/pdf/FSEC-CR-934-96.pdf. Published September 1996. Accessed April 22, 2014.
12. Young W. Photovoltaic Applications for Disaster Relief. Solar Energy Center/University of Central Florida. http://www.fsec.ucf.edu/en/publications/pdf/fsec-cr-849-95.pdf. Published November 1995. Accessed April 22, 2014.
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Prehospital and Disaster Medicine
  • ISSN: 1049-023X
  • EISSN: 1945-1938
  • URL: /core/journals/prehospital-and-disaster-medicine
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed