Hostname: page-component-76fb5796d-45l2p Total loading time: 0 Render date: 2024-04-29T18:26:42.011Z Has data issue: false hasContentIssue false

The measurements of total electron yield from silver*

Published online by Cambridge University Press:  04 November 2009

A.-G. Xie*
Affiliation:
College of Math and Physics, Nanjing University of Information and Technology, Nanjing 210044, P.R. China
C.-Q. Li
Affiliation:
College of Math and Physics, Nanjing University of Information and Technology, Nanjing 210044, P.R. China
L. Wang
Affiliation:
College of Math and Physics, Nanjing University of Information and Technology, Nanjing 210044, P.R. China
Y.-J. Pei
Affiliation:
University of Science and Technology of China, P.O. Box 6022, Hefei 230029, P.R. China
Get access

Abstract

A device for measuring total electron yields in the energy range 4–65 keV from conductor was set up successfully, which was made up of electron gun system, vacuum system and electrical system. By the pulse electron gun method, the total electron yields in the energy range 4–65 keV from silver were measured, based on the relation between the secondary electron yield and total electron yield at high incident electron energy from metals, the secondary electron yields in the energy range 10–65 keV from silver were deduced. Total electron yields measured with the device were compared with theoretical values, and the deduced secondary electron yield were compared with several authors' values, the results were discussed and a conclusion was drawn that the deduced secondary electron yields and the total electron yields from silver measured with the device are credible.

Keywords

Type
Research Article
Copyright
© EDP Sciences, 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

*

This project was supported by the Science Foundation of Nanjing University of Information and Technology (Grant No. QD65).

References

Reimer, L., Drescher, H., J. Phys. D 10, 805 (1977) CrossRef
Seiler, H., J. Appl. Phys. 54, R1 (1983) CrossRef
Ono, S., Kanaya, K., J. Phys. D 12, 619 (1979) CrossRef
Reimer, L., Tolkamp, C., Scanning 3, 35 (1980) CrossRef
D.B. Wittry, Proc. 4th Conf. on X-ray Optics and Microanalysis, edited by R. Castaing et al. (Hermann, Paris, 1966), p. 168
Hunger, H.-J., Kuchler, L., Phys. Stat. Sol. (a) 56, K45 (1979) CrossRef
K.F.J. Heinrich, Proc. 4th Conf. on X-ray Optics and Microanalysis, edited by R. Castaing et al. (Hermann, Paris, 1966), p. 159
Neubert, G., Rogaschewski, S., Phys. Stat. Sol. (a) 59, 35 (1980) CrossRef
Drescher, H., Reimer, L., Seidel, M., Z. Angew. Phys. 29, 331 (1970)
Palluel, P., Compt. Rendu 224, 1492 (1947)
Moncrieff, D.A., Barker, P.R., Scanning 1, 195 (1976) CrossRef