Hostname: page-component-89b8bd64d-z2ts4 Total loading time: 0 Render date: 2026-05-06T09:30:52.572Z Has data issue: false hasContentIssue false

RETRACTED – Determination of geometrical margins in external beam radiotherapy for prostate cancer

Published online by Cambridge University Press:  04 December 2018

Mohamed Bencheikh*
Affiliation:
LISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, Morocco
Abdelmajid Maghnouj
Affiliation:
LISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, Morocco
Jaouad Tajmouati
Affiliation:
LISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, Morocco
Ahmed Dadouch
Affiliation:
LISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, Morocco
Zakariae Benjelloun
Affiliation:
LISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, Morocco
*
Author for correspondence: Mohamed Bencheikh, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, 30000, Morocco. E-mail: bc.mohamed@gmail.com

Abstract

Introduction

The focus of this study is to find the optimal clinical tumour volume (CTV) to planning tumour volume (PTV) margins for precise radiotherapy treatment of prostate cancer. The geometrical shape of the target volume posses challenges in accurately identifying the CTV to PTV margins, especially when the organ affected by cancer demonstrates anatomical variations and the surrounding organs have high radio-sensitivity, in comparison to the organ of origin of the cancer.

Materials and methods

The geometrical margins of CTV to PTV are investigated using portal imaging, in three directions. This study is carried out on 20 patients treated by the external photon beam radiotherapy of prostate cancer using standard accelerator without stereotaxic and without prostate markers.

Results and discussion

Based on previous studies and the findings of our work, we propose CTV to PTV margin of 5·84 mm in the lateral direction, of 5·1 mm in the cranio-spinal direction and of 7·3 mm in the antero-posterior direction for external photon beam radiotherapy of prostate cancer.

Conclusion

The proposed CTV to PTV margins ensure high radiotherapy treatment precision of prostate cancer.

Information

Type
Original Article
Copyright
© Cambridge University Press 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable