Hostname: page-component-6766d58669-bkrcr Total loading time: 0 Render date: 2026-05-15T17:06:21.304Z Has data issue: false hasContentIssue false

Diagnostic accuracy of the Patient Health Questionnaire 2 (PHQ-2) in Qatar’s primary care settings

Published online by Cambridge University Press:  31 January 2022

Saad Thamer Sedeeq
Affiliation:
Qatar University Health Centre, Directorate of Clinical Operations, Primary Health Care Corporation, Doha, Qatar
Mohammad Jamil Mohammad AlTamimi
Affiliation:
Qatar University Health Centre, Directorate of Clinical Operations, Primary Health Care Corporation, Doha, Qatar
Ehab Hamed
Affiliation:
Qatar University Health Centre, Directorate of Clinical Operations, Primary Health Care Corporation, Doha, Qatar
Mohamed Ahmed Syed*
Affiliation:
Department of Clinical Research, Directorate of Clinical Operations, Primary Health Care Corporation, Doha, Qatar
*
Author for correspondence: Dr Mohamed Ahmed Syed, Directorate of Clinical Operations, Primary Health Care Corporation, P.O. Box 26555, Doha, Qatar. E-mail: ahmed.sy3d@gmail.com.
Rights & Permissions [Opens in a new window]

Abstract

This cross-sectional study was designed to establish diagnostic accuracy of the Patient Health Questionnaire 2 in Qatar’s primary care population. The data required for the study were anonymously extracted from Qatar’s primary care electronic medical record system. The sensitivity, specificity, predictive values, negative values and optimal cut-off points were calculated for the tool. A total of 6921 individuals met the study’s inclusion criteria. The diagnostic accuracy of cut-off values was calculated for scores 1–6. Based on the Youden’s index (0.58), a score of 2 was identified as the most optimal cut-off. It offers a sensitivity of 88.73% and specificity of 69.31%. Further studies should aim to confirm the results using alternative study designs and to report them in accordance to population characteristics both in Qatar and internationally.

Information

Type
Short Report
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press
Figure 0

Table 1. Diagnostic accuracy of PHQ-2 scores by cut-off values