Bloodstream infections in prolonged use of axillary-placed, intra-aortic balloon-pump support: A single-center study

Published online by Cambridge University Press:  10 November 2023

Diane Dreucean
Affiliation:
Department of Pharmacy, Houston Methodist Hospital, Houston, Texas
Kevin R. Donahue
Affiliation:
Department of Pharmacy, Houston Methodist Hospital, Houston, Texas
Celia Morton
Affiliation:
Department of Pharmacy, Houston Methodist Hospital, Houston, Texas
Luma Succar
Affiliation:
Department of Pharmacy, Houston Methodist Hospital, Houston, Texas
Jill Krisl
Affiliation:
Department of Pharmacy, Houston Methodist Hospital, Houston, Texas
Tanushree Agrawal
Affiliation:
Methodist DeBakey Heart and Vascular Center, Houston Methodist Hospital, Houston, Texas
Katherine Perez
Affiliation:
Department of Pharmacy, Houston Methodist Hospital, Houston, Texas
Taylor Jaramillo
Affiliation:
University of Houston College of Pharmacy, Houston, Texas
Ju Kim
Affiliation:
Methodist DeBakey Cardiology Associates, Houston Methodist Hospital, Houston, Texas
Nadia Fida
Affiliation:
Methodist DeBakey Cardiology Associates, Houston Methodist Hospital, Houston, Texas
Ashrith Guha
Affiliation:
Methodist DeBakey Cardiology Associates, Houston Methodist Hospital, Houston, Texas
Mahwash Kassi
Affiliation:
Methodist DeBakey Cardiology Associates, Houston Methodist Hospital, Houston, Texas
Rayan Yousefzai
Affiliation:
Methodist DeBakey Cardiology Associates, Houston Methodist Hospital, Houston, Texas
Imad Hussain
Affiliation:
Methodist DeBakey Cardiology Associates, Houston Methodist Hospital, Houston, Texas
Kevin Grimes
Affiliation:
Infectious Diseases, Houston Methodist Academic Medicine Associates, Houston Methodist Hospital, Houston, Texas
Arvind Bhimaraj*
Affiliation:
Methodist DeBakey Cardiology Associates, Houston Methodist Hospital, Houston, Texas
*
Corresponding author: Arvind Bhimaraj; Email: abhimaraj@houstonmethodist.org

Abstract

Infections from prolonged use of axillary intra-aortic balloon pumps (IABPs) have not been well studied. Bloodstream infection (BSI) occurred in 13% of our patients; however, no difference in outcome was noted between those with BSI and those without. Further studies regarding protocol developments that minimize BSI risk are needed.