Hostname: page-component-77f85d65b8-hzqq2 Total loading time: 0 Render date: 2026-03-29T06:58:02.380Z Has data issue: false hasContentIssue false

Autologous incus versus titanium partial ossicular replacement prosthesis in reconstruction of Austin type A ossicular defects: a prospective randomised clinical trial

Published online by Cambridge University Press:  21 February 2017

Naragund Amith*
Affiliation:
Department of Otorhinolaryngology, Jawaharlal Nehru Medical College, Belagavi, India
Mudhol RS
Affiliation:
Department of Otorhinolaryngology, Jawaharlal Nehru Medical College, Belagavi, India
*
Address for correspondence: Dr A Naragund, Department of Otorhinolaryngology, Jawaharlal Nehru Medical College, KLE University, Belagavi, Karnataka, India E-mail: amitnargund@rediffmail.com

Abstract

Objective:

This study aimed to compare the functional and anatomical outcomes of ossiculoplasty using an autograft incus or a titanium partial ossicular replacement prosthesis for reconstructing Austin type A ossicular defects.

Methods:

Patients with Austin A ossicular defects were randomly divided into two groups: one group underwent ossiculoplasty with an autologous incus (the autologous incus group) and the other underwent ossiculoplasty with a titanium partial ossicular replacement prosthesis (the titanium prosthesis group). Otoscopic examination and audiological assessment was done pre-operatively and at 3, 6 and 12 months post-operatively.

Results:

A post-operative average air–bone gap closure of less than 20 dB was seen in 13 patients (65 per cent) in the autologous incus group and 7 (35 per cent) in the titanium prosthesis group. There were fewer post-operative complications in the autologous incus group (20 per cent) than in the titanium prosthesis group (45 per cent).

Conclusion:

Hearing outcomes and graft take up after ossiculoplasty were significantly better when an autologous incus rather than a titanium partial ossicular replacement prosthesis was used to reconstruct Austin type A ossicular defects. The major disadvantages of the titanium prosthesis were unpredictable results and more post-operative complications.

Information

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited 2017 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable