We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
This study aimed to describe the microscopic over-under cartilage tympanoplasty technique, provide hearing results and detail clinically significant complications.
Method
This was a retrospective case series chart review study of over-under cartilage tympanoplasty procedures performed by the senior author between January 2015 and January 2019 at three tertiary care centres. Cases were excluded for previous or intra-operative cholesteatoma, if a mastoidectomy was performed during the procedure or if ossiculoplasty was performed. Hearing results and complications were obtained.
Results
Sixty-eight tympanoplasty procedures met the inclusion criteria. The median age was 13 years (range, 3–71 years). The mean improvement in pure tone average was 6 dB (95 per cent confidence interval 4–9 dB; p < 0.0001). The overall perforation closure rate was 97 per cent (n = 66). Revision surgery was recommended for a total of 6 cases (9 per cent) including 2 post-operative perforations, 1 case of middle-ear cholesteatoma and 3 cases of external auditory canal scarring.
Conclusion
Over-under cartilage tympanoplasty is effective at improving clinically meaningful hearing with a low rate of post-operative complications.
To determine whether central findings from vestibular tests predict abnormal findings on magnetic resonance imaging.
Method
This study was a retrospective case series at a tertiary referral centre. The main outcome measure of this diagnostic intervention study was the positive predictive value of central vestibular findings in relation to magnetic resonance imaging abnormalities.
Results
Central vestibular findings had a 50.9 per cent positive predictive value for magnetic resonance imaging abnormalities across all age groups although they varied according to age group. Optokinetic nystagmus (p < 0.05) and abnormal findings on videonystagmography tests (p < 0.05) were the main predictors of magnetic resonance imaging abnormalities. White matter lesions constituted the bulk of the central lesions on magnetic resonance imaging followed by cortical and cerebellar atrophy.
Conclusion
Central vestibular findings had a 50.9 per cent positive predictive value for magnetic resonance imaging abnormalities across all age groups. Magnetic resonance imaging is medically justified to further evaluate patients with central findings on vestibular studies. Therefore, it is reasonable to request magnetic resonance imaging in these patients.