Overview
The primary purpose of a lightning grounding system is to provide a means to direct lightning current from the down conductors into the Earth while minimizing the voltage rise on the protection system. For example, if a relatively high peak current Ip of 100 kA is injected into a grounding electrode with a resistance Rgr of 25 ohms, the peak voltage Vp on the metal components of the above-ground protection system due to the current flowing through the resistance Rgr will be Vp = Rgr × Ip, and hence will be equal to 2.5 × 106 volts (see Sections 2.3 and 4.4). This voltage level will lead to side flashes from the above-ground system to any isolated (or grounded at a distance) conducting bodies (metallic or human) within about 5 m of the protection system, since the average electric field for breakdown in air is about 500 kV m− 1 (see Section 3.3). To eliminate such side flashes and the danger to individuals near the protection system, one should bond (electrically connect) nearby metallic objects to the lightning protection system conductors. Since half of the peak lightning currents for first strokes are larger than about 30 kA and 90 percent are larger than about 10 kA, and since it is generally impractical to obtain grounding resistances below about 10 ohms except in the very best conducting soils, the lowest expected peak voltage on a down-conductor system will generally be hundreds of thousands of volts.
To save this book to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Find out more about the Kindle Personal Document Service.
To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.
To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.