Skip to main content Accessibility help
×
Home

Measurement of soft tissue composition by dual energy X-ray absorptiometry

  • Susan A. Jebb (a1)
    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      Measurement of soft tissue composition by dual energy X-ray absorptiometry
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      Measurement of soft tissue composition by dual energy X-ray absorptiometry
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      Measurement of soft tissue composition by dual energy X-ray absorptiometry
      Available formats
      ×

Abstract

Copyright

References

Hide All
Aloia, J., Vaswani, A., Ma, R. & Flaster, E. (1995). Comparative study of body composition by dual energy X-ray absorptiometry. Journal of Nuclear Medicine 36, 13921397.
Baumgartner, R., Stauber, P., McHugh, D., Koehler, K. & Garry, P. (1995). Cross-sectional age differences in body composition in persons 60 + years of age. Journal of Gerontology. A-Biological and Medical Sciences 50, 307316.
Beshyah, S., Freemantle, C., Thomas, E., Page, B., Murphy, M. & Johnston, D. (1995). Comparison of measurements of body composition by total body potassium, bioimpedance analysis, and dual energy X-ray absorptiometry in hypopituitary adults before and during growth hormone therapy. American Journal of Clinical Nutrition 61, 11861194.
Brunton, J., Bayley, H. & Atkinson, S. (1993). Validation and application of dual energy X-ray absorptiometry to measure bone mass and body composition in small infants. American Journal of Clinical Nutrition 58, 839845.
Chan, G. M. (1992). Performance of dual energy X-ray absorptiometry in evaluating bone, lean body mass and fat in pediatric subjects. Journal of Bone Mineral Research 7, 369374.
Chilibeck, P., Calder, A., Sale, D. & Webber, C. (1994). Reproductibility of dual energy X-ray absorptiometry. Canadian Association of Radiologists Journal 45, 297392.
Coward, W., Parkinson, S. & Murgatroyd, P. (1988). Body composition measurements for nutrition research. Nutrition Research Reviews 1, 115124.
Ellis, K., Shypailo, R., Pratt, J. & Pond, W. (1994). Accuracy of dual energy X-ray absorptiometry for body composition measurements in children. American Journal of Clinical Nutrition 60, 660665.
Ellis, K., Shypailo, R., Schoknecht, P. & Pond, W. (1995). Neutron activation analysis criterion method for evaluation of dual energy X-ray absorptiometry measurements in infants. Journal of Radioanalytical and Nuclear Chemistry 195, 139144.
Formica, C., Atkinson, M. G., Nyyulasi, I., McKay, J., Heale, W. & Seeman, E. (1993). Body composition following hemodialysis: studies using dual energy X-ray absorptiometry and bioelectrical impedance analysis. Osteoporosis International 3, 192197.
Fuller, N., Jebb, S. A., Laskey, M., Coward, W. & Elia, M. (1992 a). Four component model for the assessment of body composition in humans: comparison with alternative methods and evaluation of the density and hydration of fat free mass. Clinical Science 82, 687693.
Fuller, N., Laskey, M. & Elia, M. (1992 b). Assessment of the composition of major body regions by dual energy X-ray absorptiometry (DEXA) with special reference to limb muscle mass. Clinical Physiology 12, 253266.
Going, S., Massett, M., Hall, M., Bare, L., Root, P., Williams, D. & Lohman, T. (1993). Detection of small changes in body composition by dual energy X-ray absorptiometry. American Journal of Clinical Nutrition 57, 845850.
Gotfredsen, A., Jensen, J., Borg, J. & Christiansen, C. (1986). Measurement of lean body mass and total body fat using dual photon absorptiometry. Metabolism 35, 8393.
Gutin, B., Litaker, M., Islam, S., Manos, T., Smith, C. & Treiber, F. (1996). Body composition measurement in 9-11 y old children by dual energy X-ray absorptiometry, skinfold thickness measurements and bioelectrical impedance analysis. American Journal of Clinical Nutrition 63, 287292.
Hart, P., Wilkie, M., Edwards, A. & Cunningham, J. (1993). Dual energy X-ray absorptiometry versus skinfold measurements in the assessment of total body fat in renal transplant recipients. European Journal of Clinical Nutrition 47, 347352.
Hassager, C., Sorensen, S.S., Nielsen, B. & Christiansen, C. (1989). Body composition measurement by dual photon absorptiometry: comparison with body density and total body potassium measurements. Clinical Physiology 9, 353360.
Heymsfield, S., Smith, R., Aulet, M., Benson, B., Lichtman, S., Wang, J. & Pierson, R. (1990). Appendicular skeletal muscle mass: measurement by dual photon absorptiometry. American Journal of Clinical Nutrition 52, 214218.
Heymsfield, S., Wang, J., Heshka, S., Kehayias, J. & Pierson, R. (1989). Dual photon absorptiometry: comparison of bone mineral and soft tissue mass measurements in vivo with established methods. American Journal of Clinical Nutrition 49, 12831289.
Jebb, S. A. & Elia, M. (1995). Multicompartment models in health and disease. In Body Composition Techniques in Health and Disease, pp. 240254 [Davies, P. & Cole, T., editors]. Cambridge: Cambridge University Press.
Jebb, S. A., Goldberg, G., Jennings, G. & Elia, M. (1995 a). Dual energy X-ray absorptiometry measurements of body composition effects of depth and tissue thickness, including comparisons with direct analysis. Clinical Science 88, 319324.
Jebb, S. A., Osborne, R., Dixon, A., Bleehan, N. & Elia, M. (1994). Measurements of resting energy expenditure and body composition before and after treatment of small cell lung cancer. Annals of Oncology 5, 915919.
Jebb, S. A., Tarzi, M., Jennings, G. & Elia, M. (1995 b). A validation of measurements of fat mass by dual energy X-ray absorptiometry against direct analysis in an infant model. Proceedings of the Nutrition Society 54, 73A.
Jensen, M., Kanaley, J., Reed, J. & Sheedy, P. (1995). Measurement of abdominal and visceral fat with computed tomography and dual energy X-ray absorptiometry. American Journal of Clinical Nutrition 61, 274278.
Jensen, M., Kanaley, J., Roust, L., O'Brien, P., Braun, J., Dunn, W. & Wahner, H. (1993). Assessment of body composition with use of dual energy X-ray absorptiometry: evaluation and comparison with other methods. Mayo Clinic Proceedings 68, 867873.
Johansson, A., Forslund, A., Sjodin, A., Mallmin, H., Hambraeus, L. & Ljunghall, S. (1993). Determination of body-composition - a comparison of dual energy X-ray absorptiometry and hydrodensitometry. American Journal of Clinical Nutrition 57, 323326.
Koyama, H., Nishizawa, Y., Yamashita, N., Furumitsu, Y., Hagiwara, S., Ochi, H. & Morii, H. (1990). Measurement of composition changes using dual photon absorptiometry in obese patients undergoing semistarvation. Metabolism 39, 302306.
Lands, L., Heigenhauser, G., Gordon, C., Jones, N. & Webber, C. (1991). Accuracy of measurements of small changes in soft tissue mass by use of dual photon absorptiometry. Journal of Applied Physiology 71, 698702.
Laskey, M., Lyttle, K., Flaxman, M. & Barber, R. (1992). The influence of tissue depth and composition on the performance of the Lunar dual energy X-ray absorptiometer whole-body scanning mode. European Journal of Clinical Nutrition 46, 3945.
Mazess, R., Barden, H., Bisek, J. & Hanson, J. (1990). Dual energy X-ray absorptiometry for total-body and regional bone-mineral and soft tissue composition. American Journal of Clinical Nutrition 51, 11061112.
Mazess, R., Peppler, W. & Gibbons, M. (1984). Total body composition by dual photon absorptiometry. American Journal of Clinical Nutrition 40, 834839.
Ogle, G., Allen, J., Humphries, I., Lu, P., Briody, J., Morley, K., Howmann-Giles, R. & Cowell, C. (1995). Body composition assessment by dual energy X-ray absorptiometry in subjects aged 4-26 y. American Journal of Clinical Nutrition 61, 746753.
Paton, N., Macallan, D., Jebb, S. A., Pazianas, M. & Griffin, G. (1995). Dual energy X-ray absorptiometry results differ between machines. Lancet 346, 899900.
Peppler, W. W. & Mazess, R. B. (1981). Total body bone mineral and lean body mass by dual photon absorptiornetry: theory and measurement procedure. Calcified Tissue International 33, 353357.
Picaud, J., Rigo, J., Nyamugabo, K., Milet, J. & Senterre, J. (1996). Evaluation of dual energy X-ray absorptiometry for body-composition assessment in piglets and term human neonates. American Journal of Clinical Nutrition 63, 157163.
Pintauro, S. J., Nagy, T. R., Duthie, C. M. & Goran, M. I. (1996). Cross calibration of fat and lean mass by dual energy X-ray absorptiometry to pig carcass analysis in the pediatric body weight range. American Journal of Clinical Nutrition 63, 293298.
Prentice, A. (1995). Application of dual energy X-ray absorptiometry and related techniques to the assessment of bone and body composition. In Body Composition Techniques in Health and Disease, pp. 113 [Davies, P. & Cole, T., editors]. Cambridge: Cambridge University Press.
Pritchard, J., Nowson, C., Strauss, B., Carlson, J., Kaymakci, B. & Wark, J. (1993). Evaluation of dual energy Xray absorptiometry as a method of measurement of body fat. European Journal of Clinical Nutrition 47, 216228.
Rico, H., Revilla, M., Villa, L., Ruiz-Contreras, D., Hernandez, E. & Buergo, M. A. D. (1994). The four compartment models in body composition data from a study with dual energy X-ray absorptiometry and near infra-red interactance on 815 normal subjects. Metabolism 43, 417422.
Rosenfalak, A., Almdal, T., Gotfredsen, A., Hojjgaard, L. & Hilsted, J. (1995). Validity of dual energy X-ray absorptiometry scanning for determination of body composition in IDDM patients. Scandinavian Journal of Clinical and Laboratory Investigation 55, 691699.
Roubenhoff, R., Kehayias, J., Dawson-Hughes, B. & Heymsfield, S. (1993). Use of dual-energy X-ray absorptiometry in body composition studies not yet a ‘gold standard’p. American Journal of Clinical Nutrition 58, 589591.
Schlemmer, A., Hassager, C., Haarbo, J. & Christiansen, C. (1990). Direct measurement of abdominal fat by dual photon absorptiometry. International Journal of Obesity 14, 603611.
Slosman, D., Casez, J., Pichard, C., Rochat, T., Fery, F., Rizzoli, R., Bonjour, J., Morabia, A. & Donath, A. (1992). Assessment of whole-body composition with dual energy X-ray absorptiometry. Radiology 185, 593598.
Snead, D., Birge, S. & Kohrt, W. (1993). Age-related differences in body composition by hydrodensitometry and dual energy X-ray absorptiometry. Journal of Applied Physiology 74, 770775.
Stenver, D., Gotfredsen, A., Hilsted, J. & Nielsen, B. (1995). Body composition in hemodialysis patients measured by dual energy X-ray absorptiometry. American Journal of Nephrology 15, 105110.
Svendsen, O., Haarbo, J., Hassager, C. & Christiansen, C. (1993 a). Accuracy of measurements of body composition by dual energy X-ray absorptiometry in vivo. American Journal of Clinical Nutrition 57, 605608.
Svendsen, O., Hassager, C., Bergmann, I. & Christiansen, C. (1993 b). Measurement of abdominal and intraabdominal fat in post-menopausal women by dual energy X-ray absorptiometry and anthropometry comparison with computerised tomography. International Journal of Obesity 17, 4551.
Taaffe, D., Lewis, B. & Marcus, R. (1994). Regional fat distribution by dual-energy X-ray absorptiometry and application in a clinical trial of growth hormone and exercise. Clinical Science 87, 581586.
Tataranni, P. & Ravussin, E. (1995). Use of dual energy X-ray absorptiometry in obese individuals. American Journal of Clinical Nutrition 62, 730734.
Tothill, P., Avenell, A., Love, J. & Reid, D. (1994). Comparisons between Hologic, Lunar and Norland dual energy X-ray absorptiometers and other techniques used for whole-body soft tissue measurements. European Journal of Clinical Nutrition 48, 781794.
Treuth, M., Hunter, G. & Kebes-Szabo, T. (1995). Estimating intraabdominal adipose tissue in women by dual energy X-ray absorptiometry. American Journal of Clinical Nutrition 62, 527532.
van der Kooy, K. & Seidell, J. (1993). Techniques for the measurement of visceral fat a practical guide. International Journal of Obesity 17, 187196.
van Loan, M. & Mayclin, P. (1992). Body composition assessment: dual energy X-ray absorptiometry (DEXA) compared to reference methods. European Journal of Clinical Nutrition 46, 125130.
Wajchenberg, B., Bosco, A., Marone, M., Levin, S., Rocha, M., Lerario, A., Nery, M., Goldrnan, J. & Liberman, B. (1995). Estimation of body fat and lean tissue distribution by dual energy X-ray absorptiometry and abdominal body fat evaluation by computed tomography in Cushing's disease. Journal of Endocrinology and Metabolism 80, 27912794.
Wang, J., Heymsfield, S., Aulet, M., Thornton, J. & Pierson, R. (1989). Body fat from body density: underwater weighing vs. dual-photon absoxptiometry. American Journal of Physiology 256, E829E834.
Webber, J., Donaldson, M., Allison, S. & Macdonald, I. (1994). A comparison of skinfold thickness, body mass index, bioelectrical impedance analysis and dual energy X-ray absorptiometry in assessing body composition in obese subjects before and after weight loss. Clinical Nutrition 13, 177182.
Wellens, R., Chumlea, W., Guo, S., Roche, A., Reo, N. & Siervogel, R. (1994). Body composition in white adults by dual energy X-ray absorptiometry, densitometry and total body water. American Journal of Clinical Nutrition 59, 547555.

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed