Skip to main content
×
×
Home

A.02 Assessing visual functions in children with an optic pathway glioma using steady-state visual evoked potentials

  • S Zakaib Rassi (a1), L Ospina (a1), Y Samson (a1), D Saint-Amour (a1) and S Perreault (a1)...
Abstract

Background: Optic pathway gliomas (OPG) represent 5% of pediatric brain tumours. Visual acuity measures are used to evaluate treatment response. Current clinical tests to assess visual field integrity are subjective and require verbal cooperation. Thus, the objective of this study was to evaluate the clinical effectiveness of Steady State Visual Evoked Potentials (ssVEPs) to measure visual field integrity in a non-invasive and objective manner. Methods: SsVEPs were obtained in ten children with OPGs and 42 controls ages 3 to 21. The stimuli consisted of two circular dartboard patterns stimulating fovea and peripheral zones at two flickering frequencies, so that central and peripheral visual fields could be assessed simultaneously. The test consisted of eight stimuli presentations of 10 seconds. Results: Results indicate significantly lower ssVEP amplitudes in children with OPGs (M=2.52, 95% CI [1.13, 3.92]) compared to controls (M=13.26, 95% CI [8.85, 17.67]) in the central visual field (p=.021). However, no between group differences were detected in the peripheral field (p >.05). There were no significant differences between age groups (p>0.05). Conclusions: This objective, affordable, and non-invasive method appears to be effective in detecting central visual field deficits in children with OPGs rapidly and consistently.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      A.02 Assessing visual functions in children with an optic pathway glioma using steady-state visual evoked potentials
      Available formats
      ×
      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your Dropbox account. Find out more about sending content to Dropbox.

      A.02 Assessing visual functions in children with an optic pathway glioma using steady-state visual evoked potentials
      Available formats
      ×
      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your Google Drive account. Find out more about sending content to Google Drive.

      A.02 Assessing visual functions in children with an optic pathway glioma using steady-state visual evoked potentials
      Available formats
      ×
Copyright
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Canadian Journal of Neurological Sciences
  • ISSN: 0317-1671
  • EISSN: 2057-0155
  • URL: /core/journals/canadian-journal-of-neurological-sciences
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 24 *
Loading metrics...

Abstract views

Total abstract views: 45 *
Loading metrics...

* Views captured on Cambridge Core between 2nd June 2017 - 17th January 2018. This data will be updated every 24 hours.