B.03 Registered EEG technologists can accurately identify ictal and interictal epileptiform patterns on routine EEG
Published online by Cambridge University Press: 27 June 2018
Abstract
Background: Registered EEG technologists (RETs) are trained in both the technical aspects of EEG and in preliminary EEG interpretation. However, there is little research evaluating the accuracy of EEG interpretation by RETs. Methods: Retrospective study of consecutive routine EEG recordings performed at SickKids Hospital. Preliminary reports by RETs and final reports by neurophysiologists were compared in 5 domains: background activity, focal abnormalities, ictal and inter-ictal epileptiform discharges and summary. Results: 500 EEG recordings were analyzed. Sensitivity and specificity of RET reports was high for the assessment of background (85%, 93%), focal slowing (84%, 93%) and inter-ictal epileptiform discharges (92%, 90%). RET reports identified ictal EEG patterns in 32 cases vs. 29 cases identified by neurophysiologists. RET reports were 100% accurate for noting no EEG change for all of 11 cases with non-epileptic events. Conclusions: Preliminary EEG reports by RETs were sensitive and specific for all EEG domains analyzed. In the majority of cases, the preliminary interpretation made by the RET was concordant with the final report of the neurophysiologist. Given these findings, RETs may be able to participate in the screening of routine EEG recordings in order to enhance the productivity of busy EEG laboratories.