Hostname: page-component-848d4c4894-5nwft Total loading time: 0 Render date: 2024-06-04T06:34:51.861Z Has data issue: false hasContentIssue false

Invasive Electrographic Recording Techniques in Temporal Lobe Epilepsy

Published online by Cambridge University Press:  02 December 2014

F. Dubeau
Affiliation:
Department of Neurology & Neurosurgery, McGill University, Montreal, Canada
Richard S. McLachlan
Affiliation:
Department of Clinical Neurological Sciences, University of, Western Ontario, London, Canada
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The management of uncontrolled partial epilepsy is a process dependent on a multidisciplinary and analytic approach. It is necessary to understand which lesions are epileptogenic, and if they are indeed responsible for the generation of seizures. In addition to localizing seizure onset, the functional and eloquent areas of the brain need to be identified. As in many other centres, we perform resective surgeries on the basis of combined information derived from seizure semiology, EEG abnormalities, neuroimaging and other tests of cerebral function. If surface EEG recording yields inconclusive or ambiguous results, then invasive intracranial techniques using intracerebral depth or subdural electrodes can be used to improve diagnostic or prognostic accuracy. The indications, principles, results and complications of these recording techniques based on extensive experience at two epilepsy surgery centres are reviewed.

Type
Research Article
Copyright
Copyright © The Canadian Journal of Neurological 2000

References

1. Engel, J Jr., Update on surgical treatment of the epilepsies: Summary of the second international Palm Desert conference on the surgical treatment of the epilepsies (1992). Neurology 1993;43:1612.Google Scholar
2. Lüders, H, Awad, I. Conceptual considerations. In: Lüders, H (ed): Epilepsy Surgery. New York: Raven Press, 1992:5162.Google Scholar
3. Ojemann, GA, Engel, J. Acute and chronic intracranial recording and stimulation. In: Engel, J Jr, (ed): Surgical Treatment of the Epilepsies. New York: Raven Press, 1987:263288.Google Scholar
4. Spencer, SS, Sperling, MR, Shewmon, DA. Intracranial electrodes. In: Epilepsy: A Comprehensive Textbook. Engel, J and Pedley, TA (eds). Philadelphia, Lippincott-Raven Publishers, 1998:1719–47.Google Scholar
5. Cascino, GD, Jack, CR Jr, Parisi, JE, et al. Magnetic resonance imaging-based volume studies in temporal lobe epilepsy: pathological correlations. Ann Neurol 1991;30:3136.Google Scholar
6. Jack, CR Jr, Sharbrough, FW, Cascino, GD, et al. Magnetic resonance image-based hippocampal volumetry: correlation with outcome after temporal lobectomy. Ann Neurol 1992;31:138146.Google Scholar
7. Cendes, F, Andermann, F, Gloor, P, et al. MRI volumetric measurement of amygdala and hippocampus in temporal lobe epilepsy. Neurology 1993;43:719725.Google Scholar
8. Cendes, F, Dubeau, F, Andermann, F, et al. Significance of mesial temporal atrophy in relation to intracranial ictal and interictal stereo EEG abnormalities. Brain 1996;119:13171326.Google Scholar
9. King, D, Spencer, SS, McCarthy, G, Spencer, DD. Surface and depth EEG findings in patients with hippocampal atrophy. Neurology 1997;48:13631367.Google Scholar
10. Gloor, P. Neuronal generators and the problem of localization in electroencephalography: application of volume conductor theory to electroencephalography. J Clin Neurophysiol 1985;2:327354.Google Scholar
11. Gloor, P. Electroencephalography and the role of intracerebral depth electrode recordings in the selection of patients for surgical treatment of epilepsy. In: Porter, RJ, Mattson, R, Ward, AA, Dam, M, eds. Advances in Epileptology: XVth Epilepsy International Symposium. New York: Raven, 1984:433437.Google Scholar
12. Penfield, W, Jasper, H. Automatism, amnesia and mental disturbance. In: Epilepsy and the Functional Anatomy of the Human Brain. Boston: Little, Brown and Co., 1954:517519.Google Scholar
13. Wyler, AR, Ojemann, GA, Lettich, E, Ward, AA. Subdural strip electrodes for localizing epileptogenic foci. J Neurosurg 1984;60: 11951200.Google Scholar
14. Rosenbaum, TJ and Laxer, KD. Subdural electrode recordings for seizure focus localization. J Epilepsy 1989;2:129135.Google Scholar
15. Spencer, SS, Spencer, DD, Williams, PD, Mattson, R. Combined depth and subdural electrode investigation in uncontrolled epilepsy. Neurology 1990;40:747–9.Google Scholar
16. Sperling, MR, O’Connor, MJ. Comparison of depth and subdural electrodes in recording temporal lobe seizures. Neurology 1989;39: 14971504.Google Scholar
17. Brekelmans, GJF, van Emde Boas, W, Velis, DN, et al. Comparison of combined versus subdural or intracerebral electrodes along in presurgical focus lateralization. Epilepsia 1998;39:12901301.Google Scholar
18. Devinsky, O, Sato, S, Kufta, CV, et al. Electroencephalographic studies of simple partial seizures with subdural electrode recordings. Neurology 1989;39:527533.Google Scholar
19. So, NK, Gloor, P, Quesney, LF, et al. Depth electrode investigations in patients with bitemporal epileptiform abnormalities. Ann Neurol 1989;25:423431.Google Scholar
20. Talairach, J, Bancaud, J. Stereotaxic approach to epilepsy. Prog Neurol Surg 1973;5:297.Google Scholar
21. Cascino, GD, Trenerry, MR, Sharbrough, FW, et al. Depth electrode studies in temporal lobe epilepsy: relation to quantitative magnetic resonance imaging and operative outcome. Epilepsia 1995;36:230235.Google Scholar