Hostname: page-component-6766d58669-88psn Total loading time: 0 Render date: 2026-05-14T09:43:00.167Z Has data issue: false hasContentIssue false

Improved IP2 calibration method using a perturbance-based algorithm

Published online by Cambridge University Press:  19 March 2009

Karim Aoulad Ali*
Affiliation:
ST-NXP Wireless, 2 esplanade Anton Philips, Campus Effiscience, Colombelles, BP 20000, 14906 Caen Cedex 9, France. Phone: +33(0)2.31.45.6000; Fax: 3970, Emails: karim.aoulad.ali@stnwireless.com, philippe.barre@stnwireless.com Research Institute in Electrotechniques and Electronics of Nantes Atlantique (IREENA), University of Nantes, Rue Christian Pauc, La Chantrerie, BP 50609, 44306 Nantes Cedex 3, France. Phone: +33(0)2.40.68.3074; Fax: 3233, Emails: karim.aoulad.ali@etu.univ-nantes.fr, guillaume.andrieux@univ-nantes.fr, jean-francois.diouris@univ-nantes.fr.
Philippe Barré
Affiliation:
ST-NXP Wireless, 2 esplanade Anton Philips, Campus Effiscience, Colombelles, BP 20000, 14906 Caen Cedex 9, France. Phone: +33(0)2.31.45.6000; Fax: 3970, Emails: karim.aoulad.ali@stnwireless.com, philippe.barre@stnwireless.com
Guillaume Andrieux
Affiliation:
Research Institute in Electrotechniques and Electronics of Nantes Atlantique (IREENA), University of Nantes, Rue Christian Pauc, La Chantrerie, BP 50609, 44306 Nantes Cedex 3, France. Phone: +33(0)2.40.68.3074; Fax: 3233, Emails: karim.aoulad.ali@etu.univ-nantes.fr, guillaume.andrieux@univ-nantes.fr, jean-francois.diouris@univ-nantes.fr.
Jean-François Diouris
Affiliation:
Research Institute in Electrotechniques and Electronics of Nantes Atlantique (IREENA), University of Nantes, Rue Christian Pauc, La Chantrerie, BP 50609, 44306 Nantes Cedex 3, France. Phone: +33(0)2.40.68.3074; Fax: 3233, Emails: karim.aoulad.ali@etu.univ-nantes.fr, guillaume.andrieux@univ-nantes.fr, jean-francois.diouris@univ-nantes.fr.
*
Corresponding author: K.A. Ali Email: karim.aoulad.ali@etu.univ-nantes.fr

Abstract

To achieve a high IIP2 level on a mixer, static calibration techniques have been developed. Most of them are based on an intentional introduction of a calibrated mismatch in the structure of the mixer. They are performed at production stage. It is also possible to automate them but their activation is strongly limited in portable devices because of system restrictions. Furthermore, IIP2 is sensitive to system variations, thereby degrading the calibration operation. The challenge is so to make the calibration system dynamic, i.e. performing an online calibration. This paper presents a perturbance-based algorithm as part of an automatic calibration system to track the optimum IIP2 level. Measurements validate the algorithm behavior and indicate the feasibility of using it in a complete calibration system for a future on-chip implementation.

Information

Type
Original Article
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable