Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal end

  • S. J. Phee (a1), S. C. Low (a1), P. Dario (a2) and A. Menciassi (a2)

Summary

Tendon sheath actuation is found in many applications, particularly in robotic hands and surgical robots. Due to the friction between the tendon and sheath, many undesirable characteristic such as backlash, hysteresis and non-linearity are present. It is desirable to know the end-effector force and elongation of the tendon to control the system effectively, but it is not always feasible to fix sensors at the end effector. A method to estimate the end-effector parameters using only a force and position sensor at the proximal site is given. An analytical study is presented and experiments are reported to support the result, showing a maximum full-scale error of approximately 7%. This result is achieved if the shape of the sheath remains the same and buckling is negligible. The results presented in this study could contribute towards haptic development in robotics surgery.

Copyright

Corresponding author

*Corresponding author. E-mail: msjphee@ntu.edu.sg

References

Hide All
1.Tavakoli, M., Patel, R. V. and Moallem, M., “Haptic interaction in robot-assisted endoscopic surgery: a sensorized end-effector,” Int. J. Med. Rob. Comp. Asst. Sur. 1 (2), 5363 (2005).
2.Mitsushi, M., Arata, J., Tanaka, K., Miyamoto, M., Yoshidome, T., Iwata, S., Warisawa, S. and Hashizume, M., “Development of a Remote Minimally-Invasive Surgical System with Operational Environment Transmission Capability,” IEEE International Conference on Robotics and Automation, Taipei, Taiwan (Sep. 2003).
3.Zemiti, N., Ortmaier, T., Vitrani, M. A. and Morel, G., “A force controlled laparoscopic surgical robot without distal force sensing,” Springer Tracts Adv. Robot. Exp. Robot. IX 21, 153163 (2006).
4.Phee, S. J., Low, S. C., Sun, Z. L., Ho, K. Y., Huang, W. M. and Thant, Z. M., “Robotic system for no-scar gastrointestinal surgery,” Int. J. Med. Rob. Comp. Asst. Sur. 4, 1522 (2008).
5.Abbott, D. J., Becke, C., Rothstein, R. I. and Peine, W. J., “Design of an Endoluminal NOTES Robotics System,” Proceedings IEEE/RSJ International Conference on Intelligent Robots and Systems, San Diego, CA (Nov. 2007).
6.Kaneko, M., Yamashita, T. and Tanie, K., “Basic Considerations for Tendon Drive Robots,” Intenational Conference on Advanced Robotics, Pisa, Italy (Jun. 1991).
7.Kaneko, M., Wada, M., Maekawa, H. and Tanie, K., “A New Consideration on Tendon-Tension Control of Tendon-Driven Robot Hand,” Proceedings IEEE International Conference on Robotics and Automation, Sacramento, CA (Apr. 1991).
8.Kaneko, M., Paetsch, W. and Tolle, H., “Input-dependent stability of joint torque control of tendon-driven robot hands,” IEEE Trans. Ind. Electron. 2, 10571062 (Apr. 1992).
9.Palli, G. and Melchiorri, C., “Model and Control of Tendon-Sheath Transmission Systems,” Proceedings IEEE International Conference on Robotics and Automation, Orlando, FL (May 2006).
10.Agrawal, V., Peine, W. J. and Yao, B., “Modeling of a Closed Loop Cable-Conduit Transmission System,” IEEE International Conference on Robotics and Automation, Pasadena, CA (May 2008).
11.Guckert, M. L. and Naish, M. D., “Measuring the Angle of a Rotating Link Through Compliant Driving Tendons,” Canadian Conference on Electrical and Computer Engineering, Niagara Falls, ON, Canada (May 2008).

Keywords

Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal end

  • S. J. Phee (a1), S. C. Low (a1), P. Dario (a2) and A. Menciassi (a2)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed