Article contents
Calculation of the Availability of a Two-Unit Parallel System With Cold Standby
An Illustration of the Embedding Technique
Published online by Cambridge University Press: 27 July 2009
Abstract
A two-unit parallel system with cold standby, Markovian degradation of the working unit and one repair facility is considered. The calculation of the availability of this system under a control-limit repair policy is discussed. Iterative schemes for computing the availability in case of Erlangian repair-time distributions are presented along with numerical results.
- Type
- Articles
- Information
- Probability in the Engineering and Informational Sciences , Volume 3 , Issue 3 , July 1989 , pp. 341 - 353
- Copyright
- Copyright © Cambridge University Press 1989
References
- 1
- Cited by