The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels

Subject: Engineering

Published online by Cambridge University Press:  17 December 2020

Duarte Dias
Affiliation:
IDMEC, Mechanical Engineering Department, Instituto Superior Técnico, Universidade de Lisboa, Lisbon 1049-001, Portugal
Duarte Sampaio
Affiliation:
IDMEC, Mechanical Engineering Department, Instituto Superior Técnico, Universidade de Lisboa, Lisbon 1049-001, Portugal
Goncalo Silva
Affiliation:
IDMEC, Mechanical Engineering Department, Instituto Superior Técnico, Universidade de Lisboa, Lisbon 1049-001, Portugal
Viriato Semiao*
Affiliation:
IDMEC, Mechanical Engineering Department, Instituto Superior Técnico, Universidade de Lisboa, Lisbon 1049-001, Portugal
*
*Corresponding author. E-mail: viriato.semiao@tecnico.ulisboa.pt

Abstract

Blood-side resistance to oxygen transport in extracorporeal membrane blood oxygenators (MBO) depends on fluid mechanics governing the laminar flow in very narrow channels, particularly the hemodynamics controlling the cell free layer (CFL) built-up at solid/blood interfaces. The CFL thickness constitutes a barrier to oxygen transport from the membrane towards the erythrocytes. Interposing hemicylindrical CFL disruptors in animal blood flows inside rectangular microchannels, surrogate systems of MBO mimicking their hemodynamics, proved to be effective in reducing (ca. 20%) such thickness (desirable for MBO to increase oxygen transport rates to the erythrocytes). The blockage ratio (non-dimensional measure of the disruptor penetration into the flow) increase is also effective in reducing CFL thickness (ca. 10–20%), but at the cost of risking clot formation (undesirable for MBO) for disruptors with penetration lengths larger than their radius, due to large residence times of erythrocytes inside a low-velocity CFL formed at the disruptor/wall edge.

Information

Type
Research Article
Information
Result type: Novel result
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (http://creativecommons.org/licenses/by/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided that no alterations are made and the original article is properly cited. The written permission of Cambridge University Press must be obtained prior to any commercial use and/or adaptation of the article.
Copyright
© The Author(s), 2020. Published by Cambridge University Press
Figure 0

Figure 1. Illustrative SEM images of some microchannels and sketch of the cavity and zigzag disruptors arrangements: (a) SEM image of cavity microchannel ($ \times 30 $); (b) SEM image of zigzag microchannel ($ \times 35 $); (c) SEM image of CFL disruptor with the largest penetration length ($ \times 250 $); (d) SEM image of CFL disruptor with the smallest penetration length ($ \times 400 $); (e) top view sketches of the used zigzag and cavity microchannel arrangements and corresponding dimensions ($ {D}_0 $ – disruptor diameter; $ W $ – microchannel width; $ {L}_e $ – distance between disruptors; $ {x}_{\mathrm{disr}} $ – disruptor penetration length. Note – Visual inspection of magnified images acquired both with an optical microscope (objective ×40) and SEM (up to ×500) allowed for the assessment of the good quality of the microchannels (walls smoothness and good definition and perpendicular level of the walls).

Figure 1

Table 1. Actual height and width (assessed from SEM images) of the manufactured microchannels. Dimensions are defined in Figure 1 (e). R: reference microchannel (no disruptors); Ci: cavity-flow type; Zi: zigzag-flow type.

Figure 2

Figure 2. Effect of aging on the viscosity of blood of different animals [⋄ 3 hours after collecting blood; □ 10 hours after collecting blood; △ 24 hours after collecting blood; $ \times $ 48 hours after collecting blood; $ \ast $ 3 days after collecting blood; ∘ 7 days after collecting blood; $ + $ 15 days after collecting blood]: (a) horse blood ($ {H}_t\approx $40%, at 25 °C); (b) dog blood ($ {H}_t\approx $46%, at 25 °C).

Figure 3

Figure 3. Thickness of CFL as function of the volumetric flowrate and blockage ratio (non-dimensional degree of the disruptor penetration into the flow). (a,b) Horse and dog blood flows [□ microchannel R (free of CFL disruptors); △ zigzag-flow type microchannel Z1; ▲ cavity-flow type microchannel C1]; CFL measured at the wall region opposing the 1st disruptor in microchannels Z1 and C1; (c,d) CFL thickness after some disruptors for horse and dog blood flows in microchannel Z1; CFL measured [□ right above 13th disruptor; ■ right above 14th disruptor; △ wall opposite to the 13th disruptor; ▲ wall opposite to the 14th disruptor]; (e) Thickness of CFL at the wall opposing the disruptor as function of the blockage ratio for horse blood flows in zigzag-flow type microchannels Z1, Z4 and Z5 [⋄ 10 $ \mu \mathrm{l}/\min $, 1st disruptor; 10 $ \mu \mathrm{l}/\min $, 2nd disruptor; 10 $ \mu \mathrm{l}/\min $, 14th disruptor; △ 25 $ \mu \mathrm{l}/\min $, 1st disruptor; ▲ 25 $ \mu \mathrm{l}/\min $, 2nd disruptor; ▲ 25 $ \mu \mathrm{l}/\min $, 14th disruptor]; (f) Thickness of CFL at the wall opposing the disruptor as function of the blockage ratio for dog blood flows in cavity-flow type microchannels C1, C4 and C5 [∘ 10 $ \mu \mathrm{l}/\min $, 1st disruptor; • 10 $ \mu \mathrm{l}/\min $, 5th disruptor; □ 25 $ \mu \mathrm{l}/\min $, 1st disruptor; ■ 25 $ \mu \mathrm{l}/\min $, 5th disruptor].Note – For the cavity arrangements, CFL exhibited a non-linear increase of its thickness with the flowrate at the downstream disruptors region.

Figure 4

Figure 4. Illustration, for a blood flow around a disruptor with its penetration length into the flow $ {x}_{\mathrm{disr}} $ larger than its radius $ {D}_0/2 $, of the large residence time of a RBC inside the CFL upstream and close to the disruptor edge (highlighted with a circle marker) in comparison with that of another RBC at the plasma/erythrocytes interface (highlighted with a square marker). Flow images at that region for different instants: (a) t = 0 s; (b) t = 0.01 s; (c) t = 0.02 s; (d) t = 0.03 s; (e) t = 0.04 s; (f) t = 0.26 s.Note – These images, extracted from hundreds of the sequential images acquired with a frame rate of 2000 fps (0.5 ms between consecutive frames), exhibit a partial top view of a disruptor with the flow coming from the top to the bottom of each image. There was no experimental evidence of a similar phenomenon for blood flow around disruptors with penetration lengths $ {x}_{\mathrm{disr}} $ smaller than or equal to their radius $ {D}_0/2 $.

Supplementary material: PDF

Dias et al. supplementary material

Dias et al. supplementary material

Download Dias et al. supplementary material(PDF)
PDF 24 MB
Reviewing editor:  Maria Norberta De Pinho Universidade de Lisboa Instituto Superior Tecnico, Lisboa, Portugal, 1049-001
This article has been accepted because it is deemed to be scientifically sound, has the correct controls, has appropriate methodology and is statistically valid, and has been sent for additional statistical evaluation and met required revisions.

Review 1: The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels

Conflict of interest statement

Reviewer declares none

Comments

Comments to the Author: The manuscript addresses a very important and timely topic. The presented experimental results are very interesting and will be valuable for further work on the improvement of mass transfer in blood oxygenators.

Specific comments:

Introduction:

• First sentence: use ‘temporarily’ instead of ‘interim’.

• Line 7: not sure ‘fluid mechanics’ is the right expression here, as this basically refers to the science. Maybe replace by ‘flow characteristics of the blood flow...’, or similar

Methods:

• Please explain how exactly the thickness of the CFL layer was determined.

• Last sentence of methods: was the actual height taken at one specific location or at more points? How big is the variation within one channel? The error is meant between set and real height/width?

• Was wall smoothness measured? Or how do you testify from the SEM images?

Results and Discussion:

• Last sentence on page 2: the sentence is not very clear, please re-formulate.

• Figure 4: How were the locations of individual RBCs and their residence times determined in the flow images? Please explain.

• Page 5, last sentence of first paragraph: have the same visualizations as in Fig. 4 been made for other penetration lengths or how do the authors predict that the risk of clot formation only occurs for penetration length greater than radius? Please explain.

Presentation

Overall score 4.7 out of 5
Is the article written in clear and proper English? (30%)
4 out of 5
Is the data presented in the most useful manner? (40%)
5 out of 5
Does the paper cite relevant and related articles appropriately? (30%)
5 out of 5

Context

Overall score 5 out of 5
Does the title suitably represent the article? (25%)
5 out of 5
Does the abstract correctly embody the content of the article? (25%)
5 out of 5
Does the introduction give appropriate context? (25%)
5 out of 5
Is the objective of the experiment clearly defined? (25%)
5 out of 5

Analysis

Overall score 4.4 out of 5
Does the discussion adequately interpret the results presented? (40%)
4 out of 5
Is the conclusion consistent with the results and discussion? (40%)
5 out of 5
Are the limitations of the experiment as well as the contributions of the experiment clearly outlined? (20%)
4 out of 5

Review 2: The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels

Conflict of interest statement

Reviewer declares none

Comments

Comments to the Author: The paper presents important results obtained in a surrogate MBO system used to study the effect of disruptors in microchannels. The paper is in general clear and well written but there are some phases that should be rewritten: i) pag.2 – “… ,as illustrated in figures 1(a,b) and 1(c,d) for cavity- and zigzag-flow types, respectively, …”, because fig b corresponds to a zigzag type; ii) “Figures 3 (a,b) evidence the systematic CFL thickness increase with flowrate in microchannel R”, in fact there is an increase for all types of microchannels, but it is more pronounced in the R type; iii) “:its larger hematocrit renders space available at the flow central region for RBC to migrate smaller”, this phase is confusing and should be clearer.

In page 3, the authors suggest that zigzag arrangement is preferable, but do not show or refer the results obtained for the cavity arrangement.

The last paragraph of the results should state clearly that the “dead volume” cavity in the disruptor only exists in the systems where xdisr is greater than D0/2 and that is shown in fig. 4.

Figure 4 caption should refer that it is a partial top view of a disruptor with the flow coming from the top to the bottom of the image. The authors should also refer (maybe in the introduction) that the flow inside the microchannels is always laminar and that the CFL layer dimensions are not related to the limit layer.

Presentation

Overall score 4.3 out of 5
Is the article written in clear and proper English? (30%)
4 out of 5
Is the data presented in the most useful manner? (40%)
4 out of 5
Does the paper cite relevant and related articles appropriately? (30%)
5 out of 5

Context

Overall score 4.8 out of 5
Does the title suitably represent the article? (25%)
5 out of 5
Does the abstract correctly embody the content of the article? (25%)
5 out of 5
Does the introduction give appropriate context? (25%)
4 out of 5
Is the objective of the experiment clearly defined? (25%)
5 out of 5

Analysis

Overall score 4.6 out of 5
Does the discussion adequately interpret the results presented? (40%)
4 out of 5
Is the conclusion consistent with the results and discussion? (40%)
5 out of 5
Are the limitations of the experiment as well as the contributions of the experiment clearly outlined? (20%)
5 out of 5