Skip to main content Accessibility help
×
Hostname: page-component-848d4c4894-x5gtn Total loading time: 0 Render date: 2024-05-16T18:31:23.888Z Has data issue: false hasContentIssue false

6 - Illustrative cases and reports

Published online by Cambridge University Press:  13 August 2009

Christopher B. Cooper
Affiliation:
University of California, Los Angeles
Thomas W. Storer
Affiliation:
El Camino Community College, Los Angeles
Get access

Summary

Introduction

This chapter provides six carefully selected cases which are used to integrate the concepts of test purpose, instrumentation, testing methods, physiological responses, and interpretation of test results that have been developed in Chapters 1–5. These examples are not meant to represent an exhaustive examination of every set of responses that may be seen in clinical or performance exercise testing. Rather, these commonly encountered cases allow the reader to envisage the process of exercise testing leading to its natural conclusion – an interpretation of exercise performance based upon a systematic process of carefully applied methodologies and accurate collection of key response variables. Each case concludes with a brief statement about the outcome following exercise testing.

Case 1: Declining exercise capacity with a history of asthma (CXT: diagnostic)

Purpose

This 51-year-old male complained of declining exercise capacity. He had a history of asthma but normal pulmonary function tests. He used a salmeterol metered-dose inhaler (MDI: 2 puffs twice daily) and fluticasone MDI (2 puffs twice daily). He had never smoked. He was accustomed to running 2–3 miles, 4–5 days per week. A clinical exercise test (CXT) was requested to define his exercise limitations.

Method

A diagnostic exercise test was chosen utilizing a ramp work rate protocol on a cycle ergometer. Based on the initial physical assessment and reported exercise habits, a ramp rate of 30 W·min−1 was chosen. Expired ventilation was measured using a two-way breathing valve and hot wire flow transducer. Therefore, flow–volume loops could not be obtained.

Type
Chapter
Information
Exercise Testing and Interpretation
A Practical Approach
, pp. 181 - 203
Publisher: Cambridge University Press
Print publication year: 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×